Vertiv adds 800 VDC systems for AI data centres

Vertiv adds 800 VDC systems for AI data centres

Fri, 27th Nov 2026 (Today)
Sofiah Nichole Salivio
SOFIAH NICHOLE SALIVIO News Editor

Vertiv has added 800 VDC power systems for AI compute pods and data halls, extending its direct current portfolio to three deployment levels.

The expansion builds on the earlier launch of the Vertiv PowerDirect 5000 Power Rack, giving the company offerings for rack, compute pod and data hall deployments. The portfolio spans power conversion, energy storage, distribution and protection from the medium-voltage grid to the compute tray.

The announcement comes as data centre operators assess how to support rising power demand from AI workloads. Vertiv said many are weighing 800 VDC designs as one route to higher-density computing, while alternating current and direct current systems are likely to coexist across facilities.

That mixed environment is reflected in the company's product positioning. Vertiv said operators differ by facility type, workload profile, business model and investment horizon, and presented the new systems as a way to introduce 800 VDC at different points in the power chain without requiring a full site redesign.

At rack level, the PowerDirect 5000 sits alongside the IT rack and can be configured up to 800 kW. It accepts 480 VAC input and delivers 800 VDC or ±400 VDC output, with 30 hot-pluggable 30 kW power supply units and an integrated battery backup unit designed to provide at least 50 seconds of hold-up time.

Vertiv pairs that system with the PowerDirect 3000, a 90 kW, 19-inch, 1U DC-DC converter installed inside the compute rack. The unit converts 800 VDC to 54 VDC for compute trays and is intended for operators adding high-density AI compute to existing facilities while keeping upstream AC infrastructure in place.

In that setup, one power rack can support one or two IT racks. Vertiv said this can free up 8 to 16 rack units for additional compute by moving conversion and energy storage outside the IT rack.

Pod design

For pod-level deployments, Vertiv introduced the PowerDirect 9000, a 1.5 MW 800 VDC Power Centre that converts 480 VAC to 800 VDC for an entire row or pod. It distributes power through the Vertiv PowerBar Track DC busway and tap-off boxes to PowerDirect 3000 shelves installed in each rack.

The pod-level system scales in 60 kW increments through 27 hot-pluggable power supply units. Backup comes from the EnergyCore Li5 800 VDC battery cabinet, which connects directly to the DC bus and delivers 200 kW of continuous backup, with up to six cabinets able to operate in parallel through active current sharing.

Vertiv said the pod architecture is aimed at operators deploying megawatt-class AI compute and can reduce the need for individual power racks beside each IT rack. It added that the design supports mixed AC and DC loads in the same facility, which may suit colocation sites serving tenants with different workload types and GPU generations.

Hall scale

At data hall level, the company has added the PowerNexus MV SST, a 5 MW 800 VDC solid-state transformer that converts medium-voltage AC directly to 800 VDC in a single conversion stage. According to Vertiv, the system feeds into a DC busway and removes two to three intermediate conversion steps found in conventional power trains.

The outdoor, liquid-cooled, containerised unit is designed to support a 4.8 MW super pod reference architecture without chaining multiple systems. Vertiv said the equipment also provides galvanic isolation, stable DC output and bidirectional power flow.

The data hall design is aimed at operators building AI facilities at campus scale. Vertiv said moving power conversion outdoors can recover indoor space for compute, while fewer conversion stages can reduce cumulative power losses.

Scott Armul, Chief Product and Technology Officer at Vertiv, set out the company's view of the market shift. "The 800 VDC power train is not just a new power product or conversion methodology; it is a set of architectures and system designs," Armul said.

"Delivering it takes a comprehensive portfolio that brings together power conversion, energy storage, distribution, protection, controls and safety," he added.

Armul said the systems were designed to work together. "To meet these evolving demands, Vertiv has built a system-level 800 VDC portfolio that gives customers the flexibility to implement 800 VDC across different data centre configurations. Every layer, from the medium-voltage grid to the compute tray, is designed to work together, with safety built for DC operation," he said.

Vertiv said safety measures across the portfolio include touch-proof busbars, high-voltage isolation, midpoint grounding, ground-fault detection and arc-flash prevention. It added that service procedures were developed specifically for direct current environments rather than adapted from legacy AC systems.

Kyle Keeper, Senior Vice President of Vertiv's Power Management Business Unit, said the company expects adoption patterns to vary by site type and customer need. "Different operators have different requirements, whether they're building new AI facilities, upgrading existing sites, or supporting a mix of tenants and workloads," Keeper said.

"The Vertiv 800 VDC portfolio gives each of them an architecture that fits their needs. Whether deploying at the rack, compute pod or data hall level, customers have the optionality to choose an approach that aligns with their existing infrastructure, deployment goals and power requirements. This flexibility helps them meet today's demands while creating a path to scale as their AI infrastructure evolves," he said.